DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1501TONE-PT (Tone Generator)
10
TONE-PT (Tone Generator)
NOTE:
Replacing the tone/clock circuit pack requires a special procedure which is
described in the documentation for TONE-BD. That section also describes
the LED display for this board.
The tone generator resides on the Tone/Clock circuit pack and provides all
system tones such as dial tone, busy tone, and so on. If an active tone generator
fails, its port network may not have tones (see the Tone Generator Transmission
Test #40). For instance, a user may go off-hook and hear no dial tone. This
problem will affect only users on the same port network in which the faulty
Tone-Clock circuit pack resides. The system will be able to process certain type
of calls (that is, internal calls will succeed while outgoing calls will not).
The Tone-Clock circuit pack also provides the clocks for the system and can
serve as the synchronization reference. Therefore, when resolving alarms on the
Tone-Clock circuit pack, the TDM-CLK (TDM Bus Clock) and SYNC
(Synchronization) Maintenance documentation should be utilized as well as the
TONE-BD (Tone-Clock Circuit Pack) Maintenance documentation.
See the section on TONE-BD Maintenance in this manual for a discussion of the
relationship of Tone-Clock circuit packs with the various Reliability Options.
MO Name As
It Appears in
Alarm Log
Alarm
Level
Initial System Technician
Command to Run
Full Name of
MO
TONE-PT MAJOR test tone-clock PC sh Tone Generator
TONE-PT MINOR test tone-clock PC sh Tone Generator
TONE-PT WARNING release tone-clock PC sh Tone Generator