DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-677test trunk
8
For the following output example, assume that the command that was entered
was "test tone-clock 1a".
Feature Interactions
None.
test trunk
This command will test an entire trunk group or a specific trunk group member.
Synopsis
test trunk group number
/member number [ short | long ][ repeat number | clear ]
schedule
Permissions
The following default logins may execute this command: system technician,
inads, cust, init.
Test No The actual test that is being executed.
Result The result of the individual test -"PASS," "ABORT," "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD."
Error Code A system-generated number that tells why the release failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test tone-clock 1a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A TONE-BD 46 PASS
01A TONE-BD 52 PASS
01A TONE-PT 40 PASS
01A TONE-PT 41 PASS
01A TDM-CLK 148 PASS
01A TDM-CLK 149 PASS
01A TDM-CLK 150 PASS
01A TDM-CLK 151 PASS
01A TDM-CLK 574 PASS
Command Successfully Completed