DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-716EXT-DEV ADMIN? Y (External Device Alarm)
10
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1 minute intervals a maximum
of 5 time.
2. (Maintenance Board) If the test continues to ABORT
with error code 2000, check for system powering
problems with the A carrier. Look for and resolve all
AC-POWER and CARR-POW alarms in a multicarrier
cabinet or DC-POWER alarms in a single carrier
cabinet. Then, repeat the test.
3. (Maintenance Board) If the test continues to ABORT
with a 2000 error code, check for and resolve all
maintenance circuit pack errors. Then, repeat the
test.
4. If the test continues to ABORT with a 2000 error
code, then escalate the problem.
2029
2100
2319
2320
2500
ABORT Internal System Error
1. Retry the command at 1 minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-203. TEST #120 External Device Alarm Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page