DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-853MAINT (EPN Maintenance Circuit Pack)
10
Notes:
a. A value of 0 indicates the Expansion Link in the A carrier was active when
this error occurred. A value of 1 indicates the Expansion Link in the B
carrier was active when this error occurred. To clear this problem, make
sure the Active Expansion Link is the same as that indicated by the Aux
Value.
b. Multiple values can appear in the Aux Data field. There are other errors in
the log if there is a real problem. Use these other errors to troubleshoot the
problem.
c. The serial link between the Expansion Link in the A carrier and the EPN
Maintenance circuit pack is defective.
d. The serial link between the Expansion Link in the B carrier and the EPN
Maintenance circuit pack is defective.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Major and Minor alarms on this MO may be downgraded to Warning alarms based on the value used
in the set options command.
2817 (a) 0 (b)
1
Serial Channel Loop Test
(#229)
MINOR ON test maintenance sh r 3
3073 (a) 0
1
Network Control Circuit Pack
DPR Test (#104)
MAJOR/
WARNI
NG
2
OFF test maintenance l
3329 (c) Any Serial Link Test (#337) MINOR/
WARNI
NG
2
OFF test maintenance sh r 3
3585 (d) Any Serial Link Test (#337) MINOR/
WARNI
NG
2
OFF test maintenance sh r 3
Table 10-239. EPN Maintenance Circuit Pack Error Log Entries Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page