DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-519DIOD-TRK (DIOD Trunk) [G1.2SE]
10
1001 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat test at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use
the status trunk command to determine when the port
is available for testing.
1. Retry the command at one minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1018 ABORT Test has been disabled via administration.
1. Verify that the "Maintenance Tests?" field on the
Trunk Group Form is set to "n." To enable the test,
issue the change trunk-group x command where
"x" equals the number of the trunk group to be
tested. Then change the entry in the "Maintenance
Tests?" field on the form to "y."
1005 ABORT Trunk has been administered as incoming-only; or DID
trunk group type; dial tone can only be obtained on
outgoing trunks. This is a normal condition.
Table 10-140. TEST #0 Dial Tone Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page