DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-308CO-DS1 (DS1 CO Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field set
to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service,
then the alarm will be upgraded to a MAJOR alarm.
DS1CO Trunk Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test trunk
<grp>/<mbr>
1 (a) 57408
1 (a) 57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr>
WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk
<grp>/<mbr>
257 (e) 57392 DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
513 (f) 57393 DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
769 (g) 57484
1025 DS1CO Dial Tone
Seizure Test (#314)
WARNING OFF test trunk
<grp>/<mbr>
1281 Conference Circuit
Test (#7)
MAJ/MIN/
WRN
3
ON test trunk
<grp>/<mbr> r 4
1537 NPE Crosstalk Test
(#6)
MAJ/MIN/
WRN
3
ON test trunk
<grp>/<mbr> r 3
1793 (h) ON test board PCSS l
2562(i)) 16665
2817(j) 52992
3840 (k) Port Audit and
Update Test (#36)