DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-586test hardware-group
8
Help Messages
If the system technician presses HELP after entering "test hardware-group" the
following message will be displayed:
board cabinet carrier spe system
If the system technician presses HELP after entering "test hardware-group board"
the following message will be displayed:
Enter board location: [cabinet (1-3);
carrier (A-E);slot(00-20)]
If the system technician presses HELP after entering "test hardware-group
cabinet" the following message will be displayed:
Enter cabinet (1-3)
If the system technician presses HELP after entering "test hardware-group carrier"
the following message will be displayed:
Enter carrier location:
[’cabinet’(1-3)]; carrier (A-E)
If the system technician presses HELP after entering "test hardware-group system"
the following message will be displayed:
Entry is not required
If the system technician presses HELP after entering "test hardware-group spe"
the following message will be displayed:
Entry is not required
Error Messages
If there is another "test hardware-group" active the following message will be
displayed:
Command aborted - another hardware-group
test already in progress
If an "add station" command is entered for a non-customer translated port at the
same time as it is being tested because of the "test hardware-group" command
with the ’all-ports’ option the request to "add station" will fail and the following
message will be displayed:
Object in use; please try later
If an invalid physical location is specified with the "test hardware-group board"
command the following message will be displayed:
Board invalid
If an unassigned board is specified with the "test hardware-group board"
command the following message will be displayed: