DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-460DID-TRK (DID Trunk)
10
1000 ABORT System resources required to run this test were not
available. The port may be busy with a valid call. Use
the display port PCSSpp command to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), then check the error log for error type 513
(refer to the Error Log table for a description of this
error and required actions). The port may be locked
up.
2. If the port status is idle, busyout and release the
trunk, and then retry the command at 1-minute
intervals for a maximum of 5 times.
3. If the test continues to abort, check for wiring errors
toward the CO which may cause the trunk to lock up.
4. If the wiring is OK and the test continues to abort,
replace the TN753.
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display port PCSSpp
command to determine the station extension, attendant
number, or trunk group/member number of the port. Use
the status station, status attendant, or status trunk
command to determine the service state of the port. If
the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance
Commands and Trouble-Clearing Aids", for a full
description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is
not busied out.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
Table 10-126. TEST #35 Port Diagnostic Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page