DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-555test card-mem
8
The tests in the sequence can verify the sanity of the memory card device, the
basic read/erase/write operations to the memory card, the integrity of the
translation data stored in the memory card, the function of 12 volt power supply
in TN777B NETCON circuit pack used for memory card erase/write operations,
the translation capacity of the memory card, and the consistency of data stored
in both memory cards in a High or Critical Reliability System. This command can
help system technician to trouble-shoot the hardware errors related to
maintenance objects such as "CARD-MEM", "12V-PWR", CAP-MEM, and
"FL-DATA" logged in the system hardware error log. The details of test results
and the repair procedures for recovery are described in Maintenance Service
Document associated with each maintenance object.
If the switch is a simplex system, then the "Flash Data Consistency Test" is not
executed.
Defaults
The defaults for this test command are "short" with a repeat number of "1". The
location of carrier where the memory card resides must be specified in the
command line for a High or Critical Reliability System.