DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-173BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI Port)
10
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
Tone Detectors present or some Tone Detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV (TTR Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use
the status station command for the station associated
with this port and determine when the port is available
for testing.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1005 ABORT This test is not valid for this type of translation. Ports
administered as “ASAI” or “ADJK” can not run this test,
because the B channels associated with the port are not
used by ASAI or AT&T Adjunct Links. This is a normal
condition.
2000 ABORT Response to the test was not received from the
BRI-LINE circuit pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the
circuit pack if the other ports are not in use. Reset
the circuit pack by issuing the busyout board PCSS
and the reset board PCSS commands.
2. If this result occurs again, replace the circuit pack.
Table 10-56. TEST #619 BRI Port Local TDM Loop Around — Continued
Error
Code
Test
Result Description/ Recommendation