DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-453status data-module
8
Output
For the following output example, the command that was entered is "status
data-module 301".
Feature Interactions
None.
Data Ext/Sta Ext
for Stn DM
The data module extension number. The DTDM is an exception: the
connected station extension is shown.
Port/Channel
Number
The port location of the data module (cabinet-carrier-slot-circuit). If
the data module specified is a data channel, the channel number
will be shown instead.
Service State This entry displays the status of the data module; valid states are:
— In-service/idle
— The data module is present but not in use.
— In-service/active
— The data module is present and is in use.
—Out-of-service
— The data module has been removed from service
— Disconnected
— The data module no longer appears to be present
CF Destination Ext This entry displays the call forwarding destination, if any, of the
station.
Maintenance
Busy?
Whether maintenance is testing the object, "yes" or "no".
Connected Ports Port locations to which the data module is connected
(cabinet-carrier-slot-circuit).
status data-module 301
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 301 Service State: out-of-service
Port/Channel Number: 01C1103 Maintenance Busy? no
CF Destination Ext:
Connected Ports: