Page 10-1541UDS1-BD (UDS1 Interface Circuit Pack)
10
x. For later releases of G3V4 and beyond, only error 3585 will show that this
board is receiving misframes and the AUX data shows the last misframe
count that was reported.
y. The UDS1 Interface circuit pack has detected a transient hardware logic
error (for example, program logic inconsistency). This error will disappear
when no faults are detected for 100 minutes. The value in Aux Data field
indicates the type of hardware problem.
z. Bad Translation RAM Location Found Error. This error is not
service-affecting. No action is required. A Bad Translation RAM is
detected, but the call continues by using another translation location.
aa. LAN Receive Parity Error. This error occurs when the circuit pack detects
an error in a received frame from the Packet Bus. These errors are most
likely caused by a Packet Bus problem, but may be due to a circuit pack
fault.
Refer to the PKT-BUS Maintenance documentation to determine if the
problem is isolated to this circuit pack or if the problem is caused by
Packet Bus faults.
ab. Error 3900 is used to give status information on a CPE Loopback Jack
Test. The value in the Aux Data field indicates the status of the loopback
test.
ac. Error 3901 is used to give status information on a Far CSU Loopback Test.
The value in the Aux Data field indicates the status of the loopback test.
ad. Error 3902 is used to give status information on a One-Way Span Test. The
value in the Aux Data field indicates the status of the span test.
1
—
Test is currently running.
2
—
Test failed because loopback could not be activated.
3
—
Test failed because test pattern could not be detected.
4
—
Test has been terminated.
1
—
Test is currently running.
2
—
Test failed because loopback could not be activated.
3
—
Test failed because test pattern could not be detected.
4
—
Test has been terminated.
1
—
Test is currently running.
2
—
Test has failed because test could not be activated.
3
—
Test pattern was not received from the far end.
4
—
Test has been terminated.