DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-474DIG-LINE (Digital Line)
10
Hardware Error Log Entries and Test to Clear
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
Digital Line Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port
UUCSSpp
sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to 20 None WARNING OFF
18 (c) 0 busyout port
UUCSSpp
WARNING OFF rel port
UUCSSpp
130 (d) None WARNING ON test port
UUCSSpp
sh
257 (e) 40971 None
513 0 Station (Digital)
Audits Test (#17)
WARNING(o) OFF test port
UUCSSpp
sh r 6
767 (f) 40964 None WARNING OFF
769 (g) 40963
40988
None WARNING OFF
1026(o) NONE WARNING OFF
1281 Any Station (Digital)
Audits Test (#17)
WARNING OFF test port
UUCSSpp
sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13)
MINOR/
WARNING
2
ON test port
UUCSSpp
l r 3
2049 NPE Crosstalk Test
(#9)
MINOR/
WARNING
3
ON test port
UUCSSpp
l r 3
2304 (n) None
2305 (i) 32770 None
2305 (h) 40967 None
3840 (k) 40965 None
3840 (l) 40989 None
3841 (m) 41029 None