Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1381TAPE-DAT (Tape Consistency)
10
9 FAIL The translations and announcements are different in both SPEs. The Active
SPE is the most current.
10 FAIL The translations and announcements are different in both SPEs. The
Standby SPE has the most current translations, and the Active SPE has the
most current announcements.
1. Issue the save translations command to save translations in both
SPEs.
2. Issue the save announcements command to save announcements in
both SPEs.
3. If both the translation save and announcement save pass on both
SPEs, issue the test tape long command again to resolve the alarms.
12 FAIL Load vintages and announcements are different in both SPEs. The Active
SPE has the most current announcements.
13 FAIL The translations, announcements, and load vintages are different in both
SPEs. The Active SPE has the most current translations and
announcements.
14 FAIL The translations, announcements, and load vintages are different in both
SPEs. The Standby SPE has the most current translations, and the Active
SPE has the most current announcements.
1. Follow the procedures for Error Code 4. Be sure to issue the save
announcements command.
16 FAIL Announcements are different in both SPEs. The Standby SPE has the most
current announcements.
1. Follow the procedures for Error Code 8.
Table 10-419. TEST #421 Tape Data Consistency Check Test Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page