Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-925MODEM-PT (Modem Pool Port)
10
5001 ABORT A Network Control Channel could not be allocated for
this test. This error is more closely related to the Data
Channels (1 or 3 only) on the DATA-CHL circuit pack
used for this test than the TN758 Pooled Modem circuit
pack itself. Therefore, any hardware testing or
replacement activities focus on the DATA-CHL circuit
pack. However, the Data Channels on the DATA-CHL
circuit pack normally should not be busied out, tested
with the test data-module command, or reseated in the
carrier to clear this error, since this may drop other data
calls that may be active at the time. The administration
of Data Channels 1 and 3 should be checked if this error
occurs.
1. Wait one minute and attempt the test again.
2. If the same error persists after five attempts at
one-minute intervals, escalate the problem.
5002 ABORT The Network Control Channel allocated for this test
could not be set to "maintenance busy" status.
1. Follow the repair procedures for Error Code 5001.
5003 ABORT The test was not able to establish a connection for the
digital portion of the Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
5004 ABORT The test was not able to allocate the analog portion of
the Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
5005 ABORT The test was not able to establish a connection for the
analog portion of the Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
Table 10-262. TEST #98 Modem Pool Conversion Resource Loop Around
Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page