Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-926MODEM-PT (Modem Pool Port)
10
5006 FIL The Modem Pool Port did not respond to the
"maintenance activate" message. This error is internal to
the Modem Pool circuit pack and does not involve
external equipment or interfaces. The test failed. This
error is internal to the Pooled Modem circuit pack and
does not involve external equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem
conversion resources on the circuit pack containing
the failing conversion resource.
2. If the test continues to fail, replace the Pooled
Modem circuit pack and retest.
3. If the circuit pack fails after replacement, escalate
the problem.
5007 ABORT The Network Control Channel allocated for this test did
not respond to the incoming call indication.
1. Follow the repair procedures for Error Code 5001.
5009 ABORT The Network Control Channel allocated for this test did
not handshake correctly.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit
pack using the test data-module command (refer to
the DATA-CHL maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate
the trouble report.
5010 FAIL The Data Loop Around Test failed, indicating a probable
problem with the TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5011 ABORT The Network Control Channel allocated for this test did
not disconnect properly.
1. Follow the repair procedures for Error Code 5001.
5012 ABORT The digital portion of the tested Modem Pool Port did not
disconnect properly.
1. Follow the repair procedures for Error Code 5000.
Table 10-262. TEST #98 Modem Pool Conversion Resource Loop Around
Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page