DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-194list measurements
8
Parameters
Help Messages
If the system technician presses HELP after entering "list measurements ds1", the
following list of options is displayed:
log summary
If the system technician presses HELP after entering "list measurements ds1 log"
or "list measurements ds1 summary", the following message is displayed:
Enter board location: [cabinet(1-3)];carrier(A-E);slot(00-20),
[’print’ or ’schedule’]
Error Messages
If the user enters an invalid format for a board location when entering a "list
measurements ds1 log" or "list measurements ds1 summary" command, the
following error message is displayed:
"entered value" Invalid slot address for DS1 board
If the user enters a board location that is not a DS1 board location or the location
of an unadministered DS1 when entering a "list measurements ds1 log" or "list
measurements ds1 summary" command, the following error message is
displayed:
DS1 board has not been administered
If the user enters anything other than "log" or "summary" following "list
measurements ds1", the following error message is displayed:
"entered value" is an invalid entry; please press HELP
If the system time has not been set correctly, after entering "list measurements
ds1 log ds1_location" or "list measurements ds1 summary ds1_location" the
following error message is displayed:
ds1_location The physical location of a DS1 circuit pack entered as
cabinet-carrier-slot.
print This will cause the report to be printed if a printer is linked to the MGR1
terminal.
schedule When the "schedule" option is specified, the command is validated and
then a scheduling form is displayed to allow the technician to schedule
execution of the command. The command is then placed in the
command queue and is executed at the specified time. The
information displayed by the command is sent to the system printer
instead of the screen. Refer to the Report Scheduler and System
Printer feature specification [2] for more details.