DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-142display system-parameters maintenance
8
Output
An input form is displayed with the following fields. Defaults for data entry fields
are listed in parentheses.
Product Identification This is a 10-digit number starting with 1 that identifies the switch
to an Operations Support System (OSS), for example, INADS.
First OSS Telephone
Number
The first telephone number that the switch uses to report alarms
to, for example, INADS or Trouble Tracker. The number must be
obtained from the National Customer Support Center (NCSC) or
the TSC. # and * are not allowed in the telephone number.
Abbrev Alarm Report Enables the Abbreviated Alarm Report feature for the first OSS.
(yes)
Second OSS
Telephone Number
The second telephone number that the switch uses to report
alarms to, for example, INADS or Definity SNMP. The number
must be obtained from the National Customer Support Center
(NCSC) or the TSC. # and * are not allowed in the telephone
number.
Abbrev Alarm Report Enables the Abbreviated Alarm Report feature for the second
OSS. (no)
Alarm Origination to
OSS Numbers
Indicates one of four options for alarm origination (neither):
If “both,” all Major and Minor alarms result in an automatic
call to both OSS telephone numbers. Both OSS telephone
numbers must be administered.
If “first-only,” all Major and Minor alarms result in an
automatic call to the first OSS number only. The switch does
not call the second OSS telephone number even if the
number is administered. The first OSS telephone number
must be administered
If “neither,” alarm origination does not take place. Warning
alarms are not reported to either numbers.
If “second-as-backup,” all Major and Minor alarms result in
an automatic call to the first OSS telephone number. If
calling the first OSS telephone number fails four attempts,
the switch starts to call the second OSS telephone number
as a backup until calling the first OSS telephone number
becomes successful. Both OSS telephone numbers must be
administered.
Before Release 5, the name of this field is “Alarm Origination
Activated.” If Alarm Origination is deactivated, both Cleared
Alarm Notification and Restart Notification are disabled, even
though they may still be activated in the administration.