Maintenance Commands and Trouble-Clearing Aids
Page 8-607test journal-printer
8
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
For the following output example, assume that the command that was entered
was "test journal-printer pms-log".
Port Not applicable. Will always be blank.
Maintenance Name The type of maintenance object that is being tested. If testing the
pms-log printer link the maintenance name will be PMS-PRNT, else
if testing the wakeup-log printer link the maintenance name will be
JNL-PRNT.
Alt. Name Not applicable. Will always be blank.
Test No The actual test that is being executed.
Result The result of the individual test - "PASS", "ABORT", "FAIL",
"DISABLED".
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is
provided for each MO.
test journal-printer pms-log short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
JRNL-LINK 215 PASS