Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-683test tsc-administered
8
If the specified signaling group number is out of range, the following message is
displayed:
Signaling group invalid
If the specified signaling group is not administered, the following message is
displayed:
No signaling group assigned
If the specified signaling group has no TSC assigned or the specified TSC is
unadministered, the following message is displayed:
No TSC assigned
If the specified TSC number is out of range, the following message is displayed:
Tsc index invalid
If the software data cannot be sent to the SAT, the following message is
displayed:
Error encountered, can’t complete request
If no tests can be found for the associated MO, the following message is
displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later