DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1679XXX-BD (Common Port Circuit Pack)
10
This test is executed as part of the long test sequence only for the Tone-Clock
circuit pack and DS1 interface circuit packs. All other common circuit packs can
be reset via the reset board PCSS command. The reset command executes this
test.
Table 10-495. TEST #53 SAKI Sanity Test
Error
Code
Test
Result Description/ Recommendation
none ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1005 ABORT Wrong circuit pack configuration to run this test. This
error applies only to DS1 interface circuit packs. It
means the DS1 interface circuit pack is providing timing
for the system and, therefore, it cannot be reset without
major system disruptions.
1. If the circuit pack needs to be reset, set
synchronization to another DS1 interface circuit
pack or the Tone-Clock circuit pack and try again.
Refer to SYNC (Synchronization) Maintenance
documentation.
1015 ABORT Port is not out-of-service.
1. Busy out the circuit pack.
2. Execute command again.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pack initializes correctly.
1. Run the Short Test Sequence.
Continued on next page