DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1426TIE-DS1 (DS1 Tie Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
DS1 Tie Trunk Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test trunk
<grp>/<mbr> sh r 1>
1 (a) 57476
57477
57485
57487
15 (b) Any Port Audit and
Update Test (#36)
18 (c) 0 busyout trunk
<grp>/<mbr>
WARNING OFF release trunk
<grp>/<mbr>
130 (d) None WARNING ON test trunk
<grp>/<mbr>
257 (e) 57473
57474
513(f) 57392 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
2
769(g) 57393 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
2
1025 DS1 Tie Trunk
Seizure (Test #136)
MAJ/MIN/
WRN
3
OFF test trunk
<grp>/<mbr> r 2
1281 Conference Circuit
(Test #7)
MAJ/MIN/
WRN
3
ON test trunk
<grp>/<mbr> l r 4
1537 NPE Crosstalk
Test (#6)
MAJ/MIN/
WRN
3
ON test trunk
<grp>/<mbr> l r 3
1793 (h) test board PCSS long
2305(i) 50944 DS1 Tie Trunk
Seizure Test (#136)
MIN/MAJ
3
OFF
Continued on next page