DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-249monitor health
8
The following display was produced by entering "monitor system health".
Feature Interactions
In a High or Critical Reliability System, if the standby SPE Emergency Transfer
Select Switch is changed and handshake is down, the displayed Emerg Trans
field will be incorrect until handshake comes up again.
The user is logged off of the system when the monitor health command is
terminated.
Mn The individual number of minor alarms associated with the cabinet is
indicated. An asterisk is used to fill the field when the number exceeds
99.
Wn The individual number of associated with the cabinet is indicated. An
asterisk is used to fill the field when the number exceeds 99.
PNC Current Port Network Connectivity (PNC) status for each of the port
networks within a cabinet is displayed. When multiple port networks
exist within a cabinet, Carriers A, B, and C are listed first and
separated from Carriers D and E by a slash (e.g. up/up). PNC status of
a port network is determined on the basis of availability of the
Expansion Archangel Link (EAL). An "up" denotes that the EAL is
available. When the EAL is not available, then a "dn" (down) is
displayed.
Time of Day The current time of day acquired from the system is displayed.
status health
ALARM SUMMARY CABINET STATUS
Major: 0
Minor: 9 Emerg Alarms
Warning: 4 Cab Trans Mj Mn Wn PNC
1 off 0| 7| 0 up
BUSY-OUT SUMMARY 2 off 0| 0| 4 up
Trunks: 0 3 n.a. 0| 2| 0 up
Stations: 0 4 off 0| 0| 0 up/up
Others: 0
PROCESSOR OCCUPANCY STATUS
Static: 3% SM: 6%
CP: 10% Idle: 81%
CRITICAL SYSTEM STATUS
Active SPE: A/auto
Duplicated? SPE:n
SPE Power: commercial
Time Source: external 9:33 TUE JAN 29 1991
# Logins: 2 - Press CANCEL to quit -