Page 10-497DIG-LINE (Digital Line)
10
6 ABORT This port may have been busied out by system
technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If this error type is present, the
release the port via the release station
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
4. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available.
1392 ABORT This port is currently a TTI port and the test will not
execute on it.
1. Verify that the port is a TTI port using either the
display port command (the display shows that the
port is a TTI port) or the list config command (the
display shows a t for the port).
2. If either list config or display port indicate that the
port is
not
a TTI port, escalate the problem. If both
commands indicate that the port is a TTI port, the
abort is correct, and no action is necessary.
2000 ABORT Response to the test request was not received within the
allowable time period.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to fail, escalate the problem.
PASS Station Audits passed. This Digital Port circuit pack is
functioning properly.
1. If complaints persist, investigate by using other port
tests, and by examining the station, wiring, and
connections.
Table 10-134. TEST #17 Station (Digital) Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page