DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-344set expansion-link
8
Error Messages
If the format of the specified expansion interface circuit pack is invalid, the
following message will be displayed:
Port/Board invalid
If the link associated with the entered EI location is already active, the following
message will be displayed:
EXP-INTF is already on active link
If the specified expansion interface is not configured in the system, the following
message will be displayed:
Board not assigned
If the specified expansion interface is already the active link, the following
message will be displayed:
EXP-INTF is already on active link
If the specified expansion interface is unable to become active, the following
message will be displayed:
Standby EXP-INTF Link is unable to take over
If there are no maintenance objects for the specified board, the following
message will be displayed:
No MO in this board
If the specified board is not an expansion interface board, the following message
will be displayed:
Address is not a valid Expansion Interface Board
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later