Page 10-1526TTR-LEV (TTR Level)
10
e. Error code 5 does not indicate a current error condition. It indicates that
the number of Call Classifier ports (CLSFY-PT) in service was below the
administered threshold, but is now equal to or greater than the threshold.
These errors are typically generated during boot time or other transitional
states when the ports are being brought into service.
f. The total number of Call Classifier ports currently in service is below the
administered threshold. To clear the alarm, refer to the repair procedure
described above.
g. There are currently no DTMR ports in service. To clear the alarm, refer to
the repair procedure described above.
h. There are currently no GPTD ports in service. To clear the alarm, refer to
the repair procedure described above.
i. There are currently no Call Classifier ports in service. To clear the alarm,
refer to the repair procedure described above.