DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-612test link
8
If the link has not been administered, then the following message is displayed:
Link not administered or not enabled
If there are no tests for the current MO, the following message is displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
Following is an sample output for the command "test link 1 long".
Port Port address on the Processor Interface board associated with
the link-id being tested.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name Not applicable.
Test No The actual test that is being executed.
Result The result of the individual test - "PASS", "ABORT", "FAIL," "NO
BOARD," "DISABLED," "EXTRA BD."
Error Code A system-generated number that tells why the test failed or
aborted. A detailed list of the codes according to "Test No." is