DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-24busyout packet-control
8
access the state of the object. The release packet-control command will return
the board to a normal operation state and initiate recovery on all point-to-point
signaling links terminated on this packet-control.
Defaults
For simplex systems, the location is optional and defaults to cabinet 1, carrier A.
For duplex systems, the cabinet default is again cabinet 1, but there is no default
for the carrier.
Parameters
Help Messages
If the system technician presses HELP after entering "busyout packet-control," the
following message is displayed:
Enter Packet Control location: [cabinet(1)];carrier(A-B)
Error Messages
If this command is entered for a packet-control that resides on the stand-by
control complex of a duplicated system, the following message is displayed:
Command only applies to the active Packet Control
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
location The location only applies to duplicated configurations. If the
configuration is a simplex, the location parameter is not used and thus
is not valid. For duplicated configurations, a "location" represents the
carrier that the packet-control resides on in the system. Valid locations
are either 1A or 1B.