DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1014PDMODULE, TDMODULE (Data Module)
10
2001 ABORT System resources required to run this test are not
available.
1. Retry the test at one-minute intervals a maximum of
five times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Rerun the test at one-minute intervals a maximum of
five times.
2. If the test continues to abort, escalate the problem.
2500 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to fail, escalate the problem.
15 FAIL The control channel between the processor and Digital
Line circuit pack is not transmitting properly. This can
cause a wide range of effects. The user may notice
nothing or the port may be totally unusable. This could
also disrupt other users.
1. Run circuit pack tests to check the Tone Generator
and the Tone Detector circuit packs using the test
board UUCSS short command.
2. Resolve any problems that are detected on the Tone
Generator circuit pack or Tone Detector circuit
pack.
3. If the Tone Generator and Tone Detector circuit
packs are functioning properly, and the test still
fails, replace the Digital Line circuit pack.
Table 10-290. TEST #13 Information and Control Channel
Local Loop Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page