DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-338CO-TRK (CO Trunk)
10
1004 ABORT The port was seized by a user for a valid call. Use the
display port UUCSSpp command to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1005 ABORT Trunk has been administered as incoming-only; dial
tone can only be obtained on outgoing trunks. This is a
normal condition.
1018 ABORT Test has been disabled via administration.
1. Verify that the "Maintenance Tests?" field on the
Trunk Group Form is set to "n". To enable the test,
issue the change trunk-group x command where
"x" equals the number of the trunk group to be
tested. Then change the entry in the "Maintenance
Tests?" field on the form to "y."
2000 ABORT Response to the test was not received within the
allowable time period.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-94. TEST #0 Dial Tone Test — Continued
Error
Code
Test
Result Description/ Recommendation