DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-40ADX16A-PT (AUDIX Analog Line/Control Link)
10
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the port is in use, it is unavailable
for certain tests. Wait until the port is idle before testing. Try (a).
1001 ABORT Could not allocate the necessary system resources to run this test. Try (a).
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to TDM-BUS Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
then try (a).
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors. Then, try (a).
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension. Use the status station command to determine the service state
of the port. If the port is in use, it is unavailable for certain tests. Wait until
the port is idle before testing. Try (a).
1005 ABORT This condition indicates that the test is not applicable when the analog port
is used in a combined modem pool. This error can be ignored.
1018 ABORT Test disabled via administration.
1. To enable the test for the particular analog station being tested, enter
the change station <extension> command and change the ‘‘Test?’’
field on the Station Form from ‘‘n’’ to ‘‘y.’’
2000 ABORT Response to the test request was not received within the allowable time
period.
2012 ABORT System could not respond to this request.
2100 ABORT Could not allocate the necessary system resources for this test. Try (a).
Any FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
Table 10-16. TEST #6 NPE Crosstalk Test — Continued