DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-356set synchronization
8
subsystem is made up of system components involved in synchronization: TDM
bus clock, DS1 trunk board, maintenance and administration software resident in
the SPE.
Defaults
No defaults.
Parameters
Help Messages
If the system technician presses HELP after entering "set synchronization," the
following message will be displayed:
Enter DS1 board location or Tone-Clock location:
[(cabinet (1-3)]; carrier (A-E))
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Can not set synchronization to standby tone clock circuit pack.
Cannot set synchronization to standby tone/clock board.
location A "location" represents the physical position of the board (DS1 trunk or
active tone/clock) that will supply a reference for synchronization. The
location of a DS1 trunk is entered as "UUcSS" where "UU" represents
the cabinet number, "c" represents the carrier, and "SS" represents the
slot position. The location of a tone/clock is entered as "UUc" where
"UU represents the cabinet number, and "c" represents the carrier. The
location of a tone/clock may also be entered as "UUcSS" where "UU
represents the cabinet number, "c" represents the carrier, and "SS"
represents the slot position. A cabinet number (1 - 3) may be entered
with or without a leading zero (0).