DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-331CO-TRK (CO Trunk)
10
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to Table 10-93 for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on the values used in the set options
command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is upgraded to a
Major alarm if 75 percent of the trunks in this trunk group are alarmed.
2561 (d) 57345 None
2817 (a) 57360 None
2817 (a) 57393 None
2817 (d) 57484 Dial Tone Test (#0) MAJ/MIN/
WRN
2
OFF test port PCSS l r 1
3073 (d) 57376 None
3329 (d) 57408 None
3329 (d) 57484 Dial Tone Test (#0) MAJ/MIN/
WRN
2
OFF test port PCSS l r 1
3585 (d) 57424 None
3840 (f) 8000 Analog
Transmission
(#844-848)
OFF
3841 (f) Analog
Transmission
(#844-848)
MINOR OFF test analog testcall
UUCSS pp r 2
Table 10-92. CO Trunk Error Log Entries — Continued
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page