DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-457DID-TRK (DID Trunk)
10
3 FAIL The nonreflective 1004 Hz tone test of the port failed. An
echo was detected from the port. Poor quality transmission
was detected to or from the port. The problem may be
off-board.
7 The conference capabilities of the port failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
129 The reflective 404-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
131 The reflective 1004-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
133 The reflective 2804-Hz tone test failed. Poor quality
transmission was detected to or from the port. The problem
may be off-board.
!
CAUTION:
The port may still be operational, or the fault may be
off-board (connections or CO). Off-board problems
also include incoming seizures or off-hook port
seizures during the test and, perhaps somewhat
unlikely, noise induced by adjacent electric power
lines. Customers having this problem should resolve
it with their local power company to temporarily
alleviate the alarm caused by the failure of this test.
The test may be disabled from trunk administration
’Test’ field. This turns off all testing for that trunk group
except for tests 6 and 36.
More information continues on the next page.
Table 10-125. TEST #33 Loop Around and Conference
Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page