DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-903MET-LINE (MET Line)
10
MET Line Ringer Update Test (#62)
In this update, a "ringer on" or a "ringer off" message is sent to the firmware to
start and stop the ringer on the set.
PASS Hybrid Line Station Audits passed.
1. Although this test always returns a PASS result, it
may enter Error Types 257 or 513 into the Error Log.
To determine if there are any problems that don’t
show up in the test result, look for these error types
in the Error Log.
2. If these errors appear in the Error Log, or if user
complaints still exist, investigate by using other
circuit pack tests, and by examining the station,
wiring, and connections.
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Check to ensure that the board translations are
correct. Use the list config command, and resolve
any problems that are found.
2. If the board was found to be correctly inserted in
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and
the port. If this is not the case, check to ensure that
there is a valid board inserted.
Table 10-257. TEST #61 MET Line Station Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page