DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-28ADX16D-B (16 Port AUDIX Circuit Pack)
10
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”.
Port-level maintenance is covered by ADX16D-PT.
DEFINITY AUDIX consists of 2 circuit packs that occupy 5 slots on a port carrier.
The tests described in this manual apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy of its own that is described in
DEFINITY AUDIX System Maintenance
, 585-300-110.
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier
designation (A, B, C, D, or E).
SS
is the number of the slot in which the circuit pack
resides (01 to 21).
MO Name (in
Alarm Log)
Alarm
Level Initial Command To Run
1
Full Name of MO
ADX16D-B MINOR test board PCSS sh AUDIX Circuit Pack
ADX16D-B WARNING test board PCSS sh AUDIX Circuit Pack