DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1591UDS1-BD (UDS1 Interface Circuit Pack)
10
Misframe Alarm Inquiry Test (#145)
Misframe Alarm indicates that framing bits observed on a UDS1 Interface circuit
pack are in error. The Misframe Alarm Inquiry Test queries the total number of
misframes that have occurred on a DS1 Interface circuit pack since the last
inquiry.
When the DS1 Interface circuit pack detects a misframe error, it will increase its
misframe counter by 1. If the counter reaches a specified threshold (i.e.- 17), a
MISFRAME-COUNT message is automatically sent to the switch maintenance
software. After the maintenance software receives the MISFRAME-COUNT
message, the Misframe Alarm Inquiry Test is initiated to collect the misframe
counts from the UDS1 Interface circuit pack.
When the threshold of misframes is reached, if the UDS1 Interface circuit pack is
supplying the system synchronization source, then a switching synchronization
source message is sent to the TDM Bus Clock. See TDM-BUS (TDM Bus)
0NO
BOARD
The test could not relate the internal ID to the port (no
board). This could be due to incorrect translations, no
board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Ensure that the board translations are correct.
Execute the add ds1 PCSS command to administer
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly,
check the error log to determine whether the board
is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the
board.
3. If the board was found to be correctly inserted in
step 1, then issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal
ID and the port.
Table 10-466. TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page