DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-129ASAI-EPT
10
ASAI-EPT
The maintenance strategy for this endpoint MO is built on maintenance facilities
offered in the Lucent ISDN-BRI protocol and in the ASAI adjuncts. Currently there
are no facilities in the protocol that provide for maintenance of set data features.
The TN800 is a PC-based platform that allows interaction of multiple applications
with DEFINITY at any time. DEFINITY Release 5 software (Native mode) supports
emulation of three types of port MOs on this board. The type of ports to be
emulated is defined by the applications running on the TN800.
NOTE:
If the TN800 is emulating BRI, the software/firmware supports a maximum
of 12 ports, but only 8 of the 12 ports can be administered at any one time.
Error Log Entries and Test to Clear Values
1. The alarm level for ASAI adjuncts is administered using the set options command. The
alarm level can be set independently for off-board and on-board alarms to WARNING,
MINOR, or MAJOR for all ASAI adjuncts in the system.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run Full Name of MO
ASAI-EPT MAJOR
1
test station extension ASAI-Adjunct
Table 10-43. ASAI-EPT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
ASAI-EPT
On/ Off
Board Test to Clear Value
0
1
0 Any Any Any test ASAI-ADJ
2 (a) 2-102 None
257 (b) Any BRI Layer 3 Query MAJ/WNG
2
OFF test station ext r 2
test data-module ext r 2
351 (c) 0 none WARNING OFF busyout and release
station
513 (d) 0 None
769 (e) 0 None MAJOR OFF
2561 (f) 0 None
2562-
2566 (g)
0 None
Continued on next page