Maintenance Commands and Trouble-Clearing Aids
Page 8-327reset system
8
Maintenance
Object Alarm Level
On/Off
Board
Fault
Severity Level
Restart
Level
STBY-SPE WARNING OFF 120 None
MEM-BD MAJOR or MINOR ON 110 Hot or Warm
MEMORY MAJOR or MINOR ON 110 Hot or Warm
STBY-SPE MAJOR ON 100 None
PROCR MAJOR ON 70 Hot or Warm
SW-CTL MAJOR ON 65 Cold 2
MEM-CARD MAJOR OFF 65 Cold 1
12V-PWR MIN ON 65 Hot
DUPINT MAJOR ON 61 Hot
CARR-POW MAJOR ON 61 Cold 2
SHDW-CIR MAJOR ON or OFF 60 Warm
SHDW-LINK MAJOR ON 60 Warm
SW-CTL MINOR ON 40 Hot
PR-MAINT MINOR ON 30 Hot
PI-BD MAJOR or MINOR ON 20 Hot
PKT-CTRL MAJOR ON or OFF 20 Hot
PKT-CTRL MINOR ON or OFF 15 Hot
PI-PT MAJOR ON 15 Hot
DATA-CHL MINOR ON 15 Hot
DATA-CON MINOR ON 15 Hot
DATA-BD MINOR ON 15 Hot
MEM-CARD MINOR ON or OFF 10 Hot
PR-MAINT MINOR OFF 8 Hot