Page 10-387DATA-CHL (Network Control Data Channel)
10
If the DATA-CHL must be busied out in order to perform maintenance testing, the
secondary administration terminal connection must be re-established by
redialing the DATA-CHL.
CDR Links
1. Issue the status smdr-link command to see if an CDR Link has been
established. If the Link State field is "Up," then the CDR Link may be using
one of the Network Control Data Channels (DATA-CHLs).
2. Issue the display system features command and go to the CDR
subsection on Page 2 of the resulting form. Note the values in the Primary
Output Extension and Secondary Output Extension fields. If the values are
extensions, then the CDR Link is using one of the Network Control Data
Channels (DATA-CHLs).
3. For each of the extensions in the Primary Output Extension and Secondary
Output Extension fields, issue the status data-module <ext> command
using the extension. Note the value in the Connected Ports field of the
resulting form. If there is a port value in the field, then the indicated port is
a Network Control Data Channel (DATA-CHL).
4. Issue the list data-module command, locate each port indicated in the
Connected Ports fields, and determine if that port has a "type" value of
"netcon." If so, then there is an CDR Link over that DATA-CHL.
System Printer Links
1. Issue the status sp-link command to see if a System Printer Link has
been established. If the Link State field is "Up," then the System Printer
Link may be using one of the Network Control Data Channels
(DATA-CHLs).
2. Issue the display system features command and go to the System
Printer subsection on Page 2 of the resulting form. Note the values in the
Primary Output Extension and Secondary Output Extension fields. If the
values are extensions, then the System Printer Link is using one of the
Network Control Data Channels (DATA-CHLs).
3. For each of the extensions in the Primary Output Extension and Secondary
Output Extension fields, issue the status data-module <ext> command
using the extension. Note the value in the Connected Ports field of the
resulting form. If there is a port value in the field, then the indicated port is
a Network Control Data Channel (DATA-CHL).
4. Issue the list data-module command, locate each port indicated in the
Connected Ports fields, and determine if that port has a "type" value of
"netcon." If so, then there is a System Printer Link over that DATA-CHL.