DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-493DIG-LINE (Digital Line)
10
Table 10-133. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT This port may have been busied out by system
technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If this error type is present, then
release the port via the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
4. If the test continues to abort, escalate the problem.
3 ABORT Station may be in ready-for-service or out-of-service
state.
1. Use status station command to verify state of
station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
4. If the test continues to abort, escalate the problem.
Continued on next page