DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1659WAE-PORT (Wideband Access Endpoint Port)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. The wideband access endpoint has been busied out by a busyout
access-endpoint <extension> command. No calls can be made to this
extension.
b. The circuit pack has been removed, or it has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. The Conference Circuit Test (#7) failed on this port. See Test #7 for repair
procedures.
d. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for repair
procedures.
e. There was a failure of the TN464C UDS1 Interface circuit pack. See
UDS1-BD Maintenance documentation for details.
f. The Port Audit and Update Test (#36) failed due to an internal system
error. Enter the status access-endpoint <extension> command and
verify the status of the port. If the wideband access endpoint is
out-of-service, enter the release access-endpoint <extension>
command to put it back to in-service. Retry the test command. If the test
continues to fail, escalate the problem.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Wideband Access Endpoint Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test access-endpoint
<extension> sh r 1
18 (a) 0 busyout
access-endpoint
WARNING OFF release access-endpoint
<extension>
130 (b) None WARNING ON test access-endpoint
<extension>
1281 (c) Conference Circuit
(Test #7)
MINOR ON test access-endpoint
<extension> l r 4
1537 (d) NPE Crosstalk Test
(#6)
MINOR ON test access-endpoint
<extension> l r 3
1793 (e) None test board PCSS long
3840 (f) Any Port Audit and
Update (Test #36)