Maintenance Object Repair Procedures
Page 10-1461TIE-TRK (Tie Trunk)
10
1003 ABORT The system could not allocate a tone receiver for the
test. The system may be oversized for the number of
Tone Detectors present, or some Tone Detectors may
be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at
one-minute intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT (Non-TN497 circuit packs only.) The port was seized by
a valid call during the test. The test has been aborted.
Use the display trunk xx command to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, ‘‘
Maintenance
Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the
port is idle before retesting.
1018 ABORT The test has been disabled via administration.
Verify that the 'Maintenance Test' field on the 'Trunk
Group' form is set to 'n'. To enable the test, issue the
'change trunk-group x' command (x equals the number
of the trunk group to be tested). Then, change the entry
in the 'Maintenance Test' field on the form to 'y'.
Table 10-443. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page