DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-516status system
8
SYSTEM CLOCK This field shows which Tone-Clock circuit pack supplies the system
clock for the cabinet being displayed.
active
This Tone-Clock is active and is supplying the system clock for
this cabinet.
standby
This Tone-Clock is standby and is ready to supply the system
clock for this cabinet if the active clock fails.
down
This Tone-Clock has failed some maintenance activity and can
not supply the system clock for this cabinet.
unavail
If the system has an EPN that is currently down, then unavail is
displayed for the Tone-Clock.
<blank>
If the system is Simplex, then the 1B Tone-Clock for the PPN will
display a blank. If the system does not have an EPN, then both
the 1A and 1B Tone-Clock for this EPN will display a blank.
SYSTEM TONE This field shows which Tone-Clock circuit pack supplies the system
tones for the cabinet being displayed.
active
This Tone-Clock is active and is supplying the system tones for
this cabinet.
standby
This Tone-Clock is standby and is ready to supply the system
tones for this cabinet if the active clock fails.
down
This Tone-Clock has failed some maintenance activity and can
not supply the system tones for this cabinet.
unavail
If the system has an EPN that is currently down, then unavail is
displayed for the Tone-Clock.
<blank>
If the system is Simplex, then the 1B Tone-Clock for the PPN will
display a blank. If the system does not have an EPN, then both
the 1A and 1B Tone-Clock for this EPN will display a blank.
TDM The TDM Bus identifier. Valid identifiers are 1A, 1B, 2A, 2B, 3A and
3B.