DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-733FL-DATA (Flash Data Consistency)
10
384 ABORT The translation memory cards are missing in both SPEs.
388 FAIL The load vintages are different in both SPEs and the translation
memory cards are missing in both SPEs.
1. Follow the procedures for Error Code 132.
416 FAIL The update file in the Active SPE is more current, and the translation
memory cards are missing in both SPEs.
1. Follow the procedures for Error Code 160.
420 FAIL The load vintages and the update files are different in both SPEs, and
the translation memory cards are missing in both SPEs. The update
file in the Active SPE is more current.
1. Follow the procedures for Error Code 164.
448 FAIL The update file in the Standby SPE is more current, and the
translation memory cards are missing in both SPEs.
1. Follow the procedures for Error Code 160.
452 FAIL The load vintages and the update files are different in both SPEs, and
the translation memory cards are missing in both SPEs. The update
file in the Standby SPE is more current.
1. Follow the procedures for Error Code 164.
PASS The load vintages, translations, announcements, and update files are
the same.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page