DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-975M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
1019 ABORT An ISDN Test Call is in progress using this
Maintenance/Test circuit pack. The Maintenance/Test
circuit pack cannot perform a self-test on one of its Digital
Ports while an ISDN Test Call is using either of the Digital
Ports. Use the list isdn-testcall command to determine
which call is using the port (form the M/T Port column).
Either wait for the test call to complete (as indicated in the
Start Time and Duration fields of the above display), or
abort the test call with the clear isdn-testcall tg/mem
command, where tg/mem is determined from the
B-channel field of the above display.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1138 ABORT This test does not run on Port 3 of the Maintenance/Test
circuit pack. This test runs only on Port 2. Look at the
results of the Digital Port Sanity Test for Port 2.
1. Run the command again for Port 2 via the test port
PCSS02 or test port PCSS02 l command.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not
available.
2500 ABORT An internal operation failed; the test could not be
completed.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to fail, escalate the problem.
Table 10-281. TEST #161 Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page