DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-770INADS (INADS Link)
10
3 0 The INADS connection is currently in use.
1. Wait 10 minutes and retry this command.
4 0 INADS did not answer the alarm origination call.
1. Verify INADS is up and running.
2. Verify the INADS phone number and switch product id are
correct via the Maintenance-Related System Parameters Form.
3. Enable alarm origination via the Maintenance-Related System
Parameters Form and test the PR-MAINT (Maintenance/Tape
Processor) by issuing the test processor a|b command. If
PR-MAINT Tests #102 and #103 do not pass, then refer to
PR-MAINT (Maintenance/Tape Processor) Maintenance
documentation.
4. Retry the command.
5 0 No INADS phone number administered.
1. Administer the INADS phone number via the
Maintenance-Related System Parameters Form.
2. Retry the command.
6 0 INADS did not send the acknowledgment message to the "test
inads alarm" message.
1. Verify the INADS phone number and switch product id are
correct via the Maintenance-Related System Parameters Form.
2. Verify INADS is up and running.
3. Retry the command.
7 0 INADS sent a negative acknowledgment to the "test inads alarm"
message.
8 0 Internal system error; system received an invalid return code.
9 0 Internal system error
1. Try the command again at 1-minute intervals up to 5 times.