DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-48cancel hardware-group
8
Output
For the following output example, assume that the command that was entered is
"busyout trunk 78/1."
Feature Interactions
None.
cancel hardware-group
This command allows a user to cancel an active "test hardware-group" command
executing in the background or foreground mode.
Synopsis
cancel hardware-group
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being busied out.
Maintenance Name The type of maintenance object that is being busied out.
Alt. Name The alternate means of identifying the maintenance object. This
field contains the extension when the object is a station, and it
contains xxx/yyy when the object is a trunk, where xxx is the trunk
group number and yyy is the member number. It contains P/xxx
when the object is a private CO line, where xxx is the private CO
line group number.
Result The result of the busyout - "PASS", "ABORT", "FAIL".
Error Code A system-generated number that tells why the busyout failed or
aborted. A detailed list of the codes can be found in the
"Busyout/Release Error Codes" section of this chapter.
busyout trunk 78/1 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1505 CO-TRK 78/01 PASS
Command successfully completed