DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1434TIE-DS1 (DS1 Tie Trunk)
10
Table 10-438. TEST #7 Conference Circuit Test
Error
Code
Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test were not
available. The port may be busy with a valid call. Use
the display port UUCSSpp command to determine the
trunk group/member number of the port. Use the status
trunk command to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
1. If the port status is active but the port is not in use
(no calls), check the error log for error type 1025
(see the error log table for a description of this error
and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may
have time slots out of service due to TDM-BUS errors.
The status health command can be used to determine
if the system is experiencing heavy traffic. Refer to the
TDM-BUS (TDM bus) Maintenance Documentation to
diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic and the port status is idle,
retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.