Table 10-134. TEST #17 Station (Digital) Audits Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT Switchhook audit timed out.
2 ABORT ID request fails, health bit returned from voice terminal is
bad.
1. Make sure voice terminal is connected and repeat
test.
2. If test fails, replace voice terminal and repeat test.
3. If the test continues to abort, escalate the problem.
3 ABORT The EPF/PTC has detected an overcurrent condition.
1. For a TN754 vintage 13 or earlier Digital Line circuit
pack, issue the test UUCSSpp/PCSSpp long
command. If Test #11 passes, then the EPF/PTC
condition has been cleared. Rerun the Short Test
Sequence. If Test #11 does not pass, follow the
repair procedures described for Test #11.
2. Look for Error Type 769 logged against DIG-LINE
and follow the procedures in the associated
footnote. If any additional problems are found after
completion of maintenance procedures, rerun the
test.
3. If the test continues to abort, escalate the problem.
4 ABORT Internal System Error
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
3. If the test continues to abort, escalate the problem.
5 ABORT Ringer update aborted due to station being in
ready-for-service or out-of-service state.
Continued on next page